| Sign In | Join Free | My burrillandco.com | 
              
  | 
      
| Ask Lasest Price | |
| Brand Name : | HongCe | 
| Model Number : | HVW-1 | 
| Certification : | Calibration certificate(cost additional) | 
| Price : | Negotiation | 
| Payment Terms : | T/T | 
| Supply Ability : | 5 Sets per month | 
| Delivery Time : | 30 working days | 
UL 1581 Cable Testing Equipment for Cable Flame Test with Vertical Flame and FT2 Flame Test
Standard of Cable Testing Equipment:
UL1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords.
Application of Cable Flame Testing Equipment:
The UL 1581 is an internationally recognised standard test for evaluating fire safety for electric cables. The UL 1581 test for flammability of cable materials gives a preliminary indication of their suitability for a particular application. The equipment is supplied as a complete system incorporating all the features necessary for ease of use and safety. It conforms to UL 1581 vertical specimen Bunsen Burner tests and associated international standards. These are:
1060 Vertical Flame and FT1 Tests
1061 Cable Flame Test
1080 VW-1 (Vertical Specimen) Flame Test
1090 Horizontal-Specimen Appliance-Wire Flame Test
1100 Horizontal-Specimen / FT2 Flame Test
Parameters of Vertical/Horizontal Wire Flame Test Apparatus:
| Working voltage | 220V/50Hz | 
| Control operation mode | PLC control, 7 inch color touch screen operation, with infrared remote control | 
| Burner standard | ASTM D 5025,diameter:9.5mm ± 0.5mm,length:100mm,made of brass | 
| Gas flow | Vertical test: 965±30ml/min or 117±3 mm;horizontal test: 440±10mL/min or 58±1mm, Flow meter adjustment  | 
| Gas pressure | 0.1MPa | 
| U type pressure gauge back pressure water column height | Vertical test: 125±10 mm;horizontal test: 45±5mm | 
| Combustion time / residual glow time | 9999X0.1S | 
| Combustion angle | 0°,20°,45°,Adjustable | 
| Test flame calibration | Temperature measuring copper head:Ф9mm±0.01mm,weight before drilling:10 ± 0 .05g | 
| Thermocouple:The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple,temperature resistance 1100° | |
| Distance between the bunsen burner port to temperature measuring copper block:Vertical test:55±1 mm;horizontal test:25mm | |
Flame height: Vertical test: Inner flame:40±2mm,Outer falme:125mm; horizontal test: Inner flame:16.5±1.5mm,Outer flame:50±4mm  | |
| Temperature rise time from 100±5°C to 700°±3°C:Vertical test:54±2S; horizontal test:84±2s | |
| Gas category | Purity>98% methane | 
Product detail picture of Flammability Testing Equipment:

                                 
                             |