IEC60332-1 Flammability Testing Equipment For Single Insulated Wire or Cable Burner Tilt 45°
Purpose:
When the wire and cable products are short circuited or exposed to
fire, the insulation or sheath may burn. In many occasions (coal
mines, ships, subways, shopping malls and other public places)
where strict fire prevention is required, the flame should not
spread in case of combustion, but extinguish itself in a certain
period of time and a certain length, which is called non flame
retardancy. In some cases, if the product does not have this
function, it will cause extremely serious personal injury and
property losses.
Therefore, in the production process, PVC, chloroprene rubber and
butylamine PVC composites are widely used as insulation and sheath
materials for products with non flame retardancy. When these
materials are burned, chlorine will be released to play a flame
retardant role. Sometimes in order to enhance the effect of flame
retardant, some flame retardant is added.
Flammability Testing Equipment
Standard: IEC60332-1-1:2004,IEC60332-1-2:2004,IEC60332-1-3:2004, IEC 60950-1,BS EN 60950-1,BS 7002, UL746A,IEC60947.1, IEC730.1. Flammability Testing Equipment
Application:Suitable for vertical burning test of single cable or optical cable products, determine the combustion characteristics of insulating materials.
Test sample:Single cable or optical cable products.
Feature:Using integral intake automatic ignition system, combustion time delay only 0.1s to ensure that the full combustion of the gas.
Parameters:
Working voltage | 220V/50Hz |
Control operation mode | Electrical control, button operation |
Blast burner | Burner opening:Φ7±0.05mm,made of brass |
Gas flow and gas category | Mixture gas:650±30mL/min propane;10±0.5L/min air,Dual flow meter adjustment |
Burning time | 9999X0.1S |
Burning angle | Tilt 45°±2°,Adjustable |
Test flame calibration Flammability Testing Equipment | Temperature measuring copper head:500W:Ф9mm±0.01mm,weight before drilling:10 ± 0 .05g |
Thermocouple:The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple,temperature resistance 1100° | |
Distance between the bunsen burner port to temperature measuring copper block:95 mm | |
Flame height:Inner flame:55±5mm,Outer flame:180±10mm | |
Temperature rise time from 100±5°C to 700°±3°C 45±5s | |
Combustion chamber | WDH=300×450×1200±25mm |
Gas | >95% propane or coal gas |
Test sample | Length:600±25mm, distance from the bottom:50mm |
Fixed horizontal support of the sample | 2, distance:550mm |
Dimension | WDH=700×450×1350mm, weight about 90kg |
![]() |