Sign In | Join Free | My burrillandco.com
Home > Electrical Appliance Tester >

0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester

    Buy cheap 0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester from wholesalers
     
    Buy cheap 0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester from wholesalers
    • Buy cheap 0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester from wholesalers
    • Buy cheap 0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester from wholesalers

    0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester

    Ask Lasest Price
    Brand Name : HongCe
    Model Number : HJ0636C
    Certification : calibration certificate (cost additional)
    Price : Negotiatable
    Payment Terms : T/T
    Supply Ability : 10 set /month
    Delivery Time : 40 days
    • Product Details
    • Company Profile

    0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester

    0-360° / s PLC intelligent integrated control Refrigerator Door Endurance Tester


    Test Project:
    IEC 60335-2-24 clause 22.112

    Doors and lids of compartments in appliances test equipment


    22.11 2 The doors and lids of compartments in appliances with a free space shall be capable of being opened from the inside.
    Compliance is checked by the following test.
    The empty appliance is disconnected from the supply, placed on a horizontal support and levelled in accordance with the instructions for installation, with castors and rollers, if any, oriented, adjusted or blocked so as to prevent the appliance from moving. Locks, if any, on doors or lids are left unlocked.
    Doors and lids are closed for a period of 15 min.
    A force is then applied to a point, equivalent to an accessible inside point, of each appropriate door or lid of the appliance, at the midpoint of the edge farthest from the hinge axis in the direction perpendicular to the plane of the lid or door.
    The force shall be applied at a rate not exceeding 15 N/s and the lid or door shall open before the force exceeds 70 N.


    IEC 62552 clause 11.2 ,clause 11.3

    Endurance test for doors ,lids and drawers


    11.2 External doors and lids
    11.2.1 Test conditions/preparation
    The ambient temperature shall be between +16 °C and +32 °C.
    The refrigerating appliance shall be switched off.
    The door shelve(s) shall be loaded in accordance with 13.3.2.8 or Clause 12, as appropriate.
    11.2.2 Opening sequence (see Figure 4)
    The movement of the door shall be controlled from an angle of 0° to an angle of opening between 5° and 15°, followed by a free movement of the door, the controlled movement being approximately sinusoidal. The opening of the door shall take place in the first quarter of the period of the cycle.
    11.2.3 Closing sequence (see Figure 4)
    The movement of the door shall be controlled from the angle of opening of 45° to an angle between 40° and 35°, followed by the free movement of the door and its closing as in normal use.
    The number of cycles per minute shall be 10 to 25.
    – For compartments with an internal temperature T W − 6 °C, external doors and lids shall withstand 100 000 opening and closing operations without deterioration which could be prejudicial to the air- tightness of the door or lid.
    – For compartments with an internal temperature T u − 6 °C, external doors and lids shall withstand 30 000 opening and closing operations without deterioration which could be prejudicial to the air-tightness of the door or lid.
    Compliance shall be checked after the procedure using the test according to Clause 9.

    11.3 External drawers
    11.3.1 Test conditions/preparation
    The ambient temperature shall be between +16 °C and +32 °C.
    The refrigerating appliance shall be switched off.
    All baskets, shelves and containers shall be loaded in accordance with Clause 12.
    11.3.2 Opening sequence (see Figure 5)
    The drawers shall be pulled out to within 15 mm to 20 mm of their fully open position.
    11.3.3 Closing sequence (see Figure 5)
    The drawers shall be closed as in normal use from within 15 mm to 20 mm of their fully open position.

    The number of cycles per minute shall be between 5 and 10.
    – For compartments with an internal temperature T W − 6 °C,
    1) single drawers shall withstand 100 000, and
    2) multiple drawers shall each withstand 50 000,
    opening and closing operations without deterioration which could be prejudicial to the air-tightness of the drawer sealing.
    – For compartments with an internal temperature T u − 6 °C, each drawer shall withstand 30 000 opening and closing operations without deterioration which could be prejudicial to the air-tightness of the drawer sealing.
    Compliance shall be checked after the procedure using the test according to Clause 9.


    Technical parameters:

    Specimen Range, Use, Principle, Structure And Use Environment
    Samples And LimitationsRefrigerating Appliances (Refrigerator)
    Test PurposesIt is used for endurance life testing of interlocks or guides for refrigerator doors or drawers to verify the reliability of interlocks; also used to assist other tests for repeated door opening and closing operations, such as defrosting test and refrigerant leak test
    Test PrincipleThe motor drives the manipulator, driving the door or cover sucked by the Vacuum sucker to reciprocate at a certain speed, to verify the reliability of interlocking device.
    Structure

    The equipment is divided into an electrical control cabinet (including load voltage regulator), a frame and a robot arm.
    Size:1500×1300×2200(mm)W×D×H
    Weight :140kg

    Operation Environment

    Power supply :AC220V±10%/50-60Hz,power :6KW
    Air source :0.5-0.7MPa Compressed air
    Place Of Use :Atmospheric pressure 80 ~ 106kpa;Ambient temperature 5~40°C;relative humidity(20~80)%RH;No violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gas, good heat dissipation

    Performance
    Test Station

    Revolving Door Action Position
    Drawer action station

    Electrical Control MethodPLC intelligent integrated control, 7-inch human-machine touch interface operation
    Drive ModeServo motor drive
    Sample Clamping MethodVacuum sucker
    Open/Close Door Speed

    Revolving Door Action:0-360°/s(1.5m/s),can be preset
    Drawer action:0-100mm/s, can be preset

    Revolving Open Close Door Angle0-90°,can be preset
    Drawer Door Opening Distance0-100mm,can be preset
    Test Times0-999999 times ,can be preset
    Load Voltage0-250V,adjustable
    Test Item And Crafting Process

    1. Refrigerator door interlock device endurance test

    Process:Vacuum sucker automatic suck the door---- Open the door to a preset angle at a preset speed(45°)---- close the door at preset speed---- Repeatedly open and close the door until reaches the test times

    2. Refrigerator drawer door endurance test
    Process:Vacuum sucker automatic suck the door---- Open the drawer to the preset distance at a preset speed(15-25mm)----Close drawers at preset speed----Repeatedly open and close the drawer until reaches the test times

    Safety Protection Device
    PowerLeakage protection, overload and short circuit protection
    MotorOverload, short circuit protection

    Picture view:


    Quality 0-360°/S PLC Intelligent Integrated Control Refrigerator Door Endurance Tester for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From: