Sign In | Join Free | My burrillandco.com
Home > Plug Socket Tester >

10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station

    Buy cheap 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station from wholesalers
     
    Buy cheap 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station from wholesalers
    • Buy cheap 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station from wholesalers
    • Buy cheap 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station from wholesalers
    • Buy cheap 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station from wholesalers
    • Buy cheap 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station from wholesalers

    10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station

    Ask Lasest Price
    Brand Name : HongCe
    Model Number : HC9903
    Certification : Calibration certificate(cost additional)
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 30 set per month
    Delivery Time : 20 days
    • Product Details
    • Company Profile

    10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station

    10±2 RPM Test Rate IEC60884 Figure 11 Testing Device For Checking Damage To Conductors Single Working Station​


    Standard:


    IEC 60884-1 'Plugs and socket-outlets for household and similar purposes – Part 1: General requirements' clause 12.2.2, 12.3.10 and figure 11


    Application:


    It is use to check whether the terminals with screw and screwless terminals can bears the mechanism force under normal operation. Mainly use to judge whether the design and structure of screw clamping terminals meet the requirement of clamp the conductors without excessive damage.


    Test sample:


    Screw terminals and screwless terminals


    Parameters:


    ModelHC9903
    Test rate10±2 RPM
    Diameter of gyration75mm
    Test times0~9999
    Weights0.3,0.4, 0.7, 0.9, 1.4kg
    Test height260, 280, 300, 320mm
    Diameter of ferrule hole6.5, 9.5, 13, 14.5mm
    StandardsIEC60884-1, IEC60669-1

    Normal Test


    1. Scale adjustment: Unlock the fixed nut of the scale position, adjust the fixture to the required height for the test and fix it.

    2. Center adjustment: use the wire hammer to find the center of the turntable. Here we need to correspond to the shape of the sample, so that the leading-out terminal of the sample is alignment.


    3. Sample installation.

    3.1. The connection terminals are connected to the corresponding wires, and clamp and fix the fixtures after installing.

    3.2. The wire are through to the corresponding bushing and install the corresponding counterweight.


    3.3. Comparison table of the weight, height and bushing as below:

    Nominal cross-sectional area of conductor ( mm²)Diameter of bushing Hole( mm)Height (mm)Mass for conductor (kg)
    0.56.52600.3
    0.756.52600.4
    1.06.52600.4
    1.56.52600.4
    2.59.52800.7
    4.09.52800.9
    6.09.52801.4
    10.09.52802.0
    16.013.03002.9
    1. The Corresponding size with mm² see IEC 60999-1.
    2. The height:±15mm.
    3. If the bushing-hole diameter is not large enough, you can choose the larger one.
    4. 2.9Kg weights are composed of 2Kg weights and 0.9Kg weights

    4. Normal test steps:

    4.1. Preset【Test Time】according to standard requirements, press<to select the preset time, then pres▲Upward or▼Downward to select the required value, and then press[SET] to confirm, time display format is 99hours 59minutes59s.(Every time the test time is changed, the reset button should be pressed to eliminate the test time which set before.)

    4.2. Press【Start】button, the device starts to run, the turntable rotate at a rate of 10r/min., after reaching to the【Test Time】,the test automatic stop and with sound prompt.

    4.3. Press the Yellow reset button to remove the voice prompt. After the test is completed, the switch of the circuit breaker should be pulled down and cut off the power supply.

    4.4. Conclusion: During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.

    10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station

    Quality 10±2 RPM test rate IEC60884 figure 11 Testing Device For Checking Damage To Conductors Single Working Station for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou HongCe Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)