Sign In | Join Free | My burrillandco.com
Home > Test Finger Probe >

UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1

    Buy cheap UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1 from wholesalers
     
    Buy cheap UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1 from wholesalers
    • Buy cheap UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1 from wholesalers
    • Buy cheap UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1 from wholesalers
    • Buy cheap UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1 from wholesalers

    UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1

    Ask Lasest Price
    Brand Name : HongCe
    Model Number : HT-U02/HT-U03
    Certification : Calibration Certificate (cost additional)
    Price : Negotiatable
    Payment Terms : T/T
    Supply Ability : 100 set/ month
    Delivery Time : 3 Days
    • Product Details
    • Company Profile

    UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1

    UL982 Probe For Uninsulated Live Parts And Film-Coated Wire Length 101.6mm Diameter 19.1


    Description in UL982 2009 Clause 58.9.2:

    In the enclosure of an appliance other than as described in 58.9.1, an opening which does not permit entrance of a 3/4 inch-diameter (19 mm) rod is acceptable if:
    a) A probe as illustrated in Figure 58.6 cannot be made to touch any uninsulated live part or moving part capable of causing injury when inserted through the opening, and Test Finger Probe
    b) A probe as illustrated in Figure 58.7 cannot be made to touch magnet wire when inserted through the opening.
    Exception: If unacceptable results are obtained using the probe illustrated in Figure 58.6 and 58.7, the probe illustrated in Figure 7.1 may be used to determine that the part is not more accessible than with a sample prior to conditioning. Test Finger Probe


    Standard:UL507-2006(PA135A)Fig 9.1, UL749 Fig 1, UL982 Fig 58.6 and UL1278 Fig 8.1(PA130A).

    UL398 Fig 8.2(PA170B),UL507(PA170D),UL749 Fig 2,UL982 Fig 58.7 and UL1278 Fig 8.2(PA140A).

    Application:It is used for the performance of the electrical equipment enclosure preventing electric shock, and the testing of coating lines of the enamel (i.e., transformers and inductors).

    Test sample:Easily accessible enclosure live parts or mechanical parts, transformers and inductors.

    Feature:Nylon handle + probe, it is manufactured according to the standard figure. Test Finger Probe


    Parameters:

    NameValueValue
    Length 1101.60mm101.60mm
    Length 214.3mm-
    Radius4.8mm6.4mm
    Diameter 112.7mm12.7mm
    Diameter 219.1mm19.1mm

    Picture for reference:

    Quality UL982 Test Finger Probe For Uninsulated Live Parts Film Coated Wire Length 101.6mm Diameter 19.1 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou HongCe Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)