Sign In | Join Free | My burrillandco.com
Home > Helium Leak Testing Equipment >

Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate

    Buy cheap Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate from wholesalers
     
    Buy cheap Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate from wholesalers
    • Buy cheap Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate from wholesalers
    • Buy cheap Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate from wholesalers
    • Buy cheap Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate from wholesalers
    • Buy cheap Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate from wholesalers

    Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate

    Ask Lasest Price
    Brand Name : HongCe
    Model Number : HJAU
    Certification : Thir party calibration certificate(cost additional)
    Payment Terms : L/C, T/T, Western Union
    Delivery Time : 120 days
    Price : Negotiatable
    • Product Details
    • Company Profile

    Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate

    Heat Exchanger Vacuum Chamber Helium Leak Test System 30 s/pc Leak Detection Rate 1.0E-5mbar.l/s


    The series of system is able to run the following tests:A. leak detection with pressure decay method to find Gross Leaks; B. Helium test with mass spectrometer to find Fine leaks.

    The series of system makes online mass production detection to be much easy, accurate and effective!


    Technical specification:

    • Cycle time:30sec./pcs. (for reference, demanded by customer)

    • Leak rate:1.0E-5mbar.l/s (relevent 2g/a R134a) (for reference, demanded by customer)

    • Test pressre:8-42bar (for reference, demanded by customer)

    • Chambers: Two (for reference, demanded by customer)

    Test Procedures:


    The system proposed has a totally automatic cycle with manual load and unload of the Products.
    The Test Cycle can be described in the following way:
    A. Manual load and sealed Products in the Test Chamber.
    B. Closure of the Chamber.
    C. Evacuation of the Chamber to a value of vacuum suitable for Leak Test with Mass Spectrometer. During the evacuation of the Chamber, the system will run the following Tests on the Products:
    D. Pressure decay to reveal Gross Leaks;
    E. Pressure discharge and Products evacuation;
    F. Reaching a vacuum value suitable for transfer, that is to put the mass spectrometer in communication with the Test Chamber.
    G. Reading of background, which is the residual Helium in the Test Chamber.
    H. Pressurization of Products with Helium.
    I.Leak test with Mass Spectrometer.
    J.Ventilation of the Test Chamber (return to atmospheric pressure), helium recovery from the products to a specific pressure (depend on chosen parameters and final evacuation of the Products).
    K.Opening of the Chamber
    L.Manual unloads of Products.


    Schematic:


    Refrigeration Parts Helium Leak Testing Equipment (On-line & Automatically Operation, Fast Cycle Time, High precision)


    HongCe adopts to famous brand hardwares to guarantee the quality:


    Vacuum pumpLeybold
    Vacuum sensorInficon
    Helium leak detectorInficon
    Presure sensorGE
    Solenoid valveBurkert
    PLCOmron
    HMIOmron

    Quality Heat Exchanger Vacuum Chamber Helium Leak Testing Solution 30 s/pc Leak Detection Rate for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou HongCe Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)